Abstract

According to the flow passage characteristic of rectangular narrow channel and the annular flow predicted analytical model of Critical Heat Flux(CHF) in round tube, the annular flow CHF analytical model in rectangular narrow channel has been gotten. This model can been used to predicted the CHF of boiling two-phase flow annular flow in rectangular narrow channel which the gap width is not less than 0.5mm. Through analysing and calculation, when the inlet width-gap width ratio of rectangular narrow channel is within 25-85, the enhancement of CHF in channel is obvious. Based on the practical and economical sides, this range can be taken as the CHF enhancement reference range of inlet dimensions in rectangular narrow channel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.