Abstract

An analytical model of an ultrasonic cross-correlation flow meter has been developed to relate the time delay measured by the meter to the mean velocity profile and statistical properties of turbulent pipe flow. In Part 2 of this two-part paper, the cross-correlation and cross-spectrum of the demodulated ultrasonic signal are obtained using the stochastic model of the turbulent velocity fluctuations from Part 1. Calculations of the bulk velocity calibration factor using computational fluid dynamics simulations of fully-developed pipe indicate that the calibration factor has a logarithmic dependence on Reynolds number. In addition, the model was used to investigate the sensitivity of the device to transducer spacing and wall roughness. It was found that increased transducer spacing and increased pipe roughness both decrease the bulk velocity calibration factor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.