Abstract

Nonconventional wastewater treatments, such as vegetation filters (VFs), are propitious systems to attenuate contaminants of emerging concern (CECs) in small municipalities. The development of standardised multiresidue and multimatrix methods suitable for measuring a reliable number of CEC in environmental samples is crucial for monitoring infiltrating concentrations and for ensuring these systems’ treatment capacity. The objective of this study is to develop and validate an analytical method for the simultaneous determination of CECs, including transformation products (TPs), with diverse physico-chemical properties, in environmental samples. The optimised method is based on sample clean-up and preconcentration by solid-phase extraction (SPE), followed by liquid chromatography electrospray ionization tandem mass spectrometry (LC-MS/MS). The method is able to detect and quantify 40 target CECs, including pharmaceuticals of different classes (analgesics, antibiotics, antihypertensives, lipid regulators, anticonvulsants, antidepressants, antiarrhythmics, beta-blockers, amongst others), hormones and lifestyle products with good reproducibility (variations below 23%), in different water matrices, and 28 CECs, in soil samples. Acceptable recoveries (65–120%) were obtained for most of the CECs in all the matrices. However in the soil samples, as complexity required a prior extraction treatment, the recovery of some analytes was affected, which reduced the number of target CECs. The achieved methodological quantification limits (0.05–5 ng/L and 0.04–1.1 ng/g levels for the water and the soil matrices, respectively) were reasonably low for most CECs. The proposed method was successfully applied to monitor CECs in a VF. The CECs detected at higher concentrations are some of the world's most widely used products (e.g. acetaminophen or caffeine and its main TP, paraxanthine). The results showed an almost 70% reduction in CEC concentrations during infiltration. The groundwater data indicated that the VF treatment operation did not affect the underlying aquifer (Cmax found in GW <1 µg/L).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call