Abstract
A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of brivaracetam in its pure form as well as in tablet dosage form. Chromatography was carried out on a Symmetry ODS RP C18,5mm, 15mm x 4.6mm column using a mixture of phosphate buffer: methanol: acetonitrile (30:35:35% v/v) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 285 nm. The retention time of the brivaracetam was 2.183. The method produces linear responses in the concentration range of 60-140μg/ml of brivaracetam. The method precision for the determination of assay was below 2.0%RSD. The method was found to be sensitive, accurate and precise useful in the quality control of bulk and pharmaceutical formulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Asian Journal of Pharmaceutical Research and Development
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.