Abstract

Abstract. This contribution contains the mechanisms for calculation of magnetic shielding effectiveness from material samples, based on measured electrical parameters. For this, measurement systems for the electrical conductivity of high and low conductive material samples with respect to the direction of current flow are presented and discussed. Also a definition of isotropic and anisotropic materials with electrical circuit diagrams is given. For prediction of shielding effectiveness for isotropic and anisotropic materials, several analytical models are presented. Also adaptions to gain a near field solution are part of this contribution. All analytical models will also be validated with an adequate measurement system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.