Abstract

As the need of the train speed increased, the existing bridges need to be evaluated, especially in dynamic responses, which are deformation and acceleration. In this study, Cisomang Bridge is modeled and analyzed due to the high-speed train SJ X2 in varying speeds, 50 km/h, 100 km/h, 150 km/h, and 200 km/h. The used of tuned mass damper also will be varied on its setting and placing. The tuned mass dampers setting be varied based on the first or second natural frequency and the placing of tuned mass damper be varied based on maximum deformation of the first or second mode. Moreover, the tuned mass damper ratio will be varied 1% and 1.6%. For all speed variations, dynamic responses of structure without TMD still fulfil the Indonesian Government Criterion based on PM 60 - 2012 but do not meet requirement of comfort criteria based on DIN-Fachbericht 101. Furthermore, only for the speed train 50km/h dynamic responses of structure fulfil safety criteria based on Eurocode EN 1990:2002, whereas the other speed variations do not meet that requirement. In the use of TMD 1% mass ratio, the structure fulfils the safety criteria for all speed variations. In the use of TMD 1.6% mass ratio, all the structure fulfils the safety and comfort criteria except 100 km/h speed which only fulfils the safety criteria.

Highlights

  • The high demand traffic triggers the development of high speed train in Indonesia, even new infrastructure will be built to accommodate “high speed train Jakarta-Bandung” by Indonesian Government

  • Only for the speed train 50km/h dynamic responses of structure fulfil safety criteria based on Eurocode EN 1990:2002, whereas the other speed variations do not meet that requirement

  • Dynamic responses which are under reviewed in this study are displacement and acceleration

Read more

Summary

Introduction

The high demand traffic triggers the development of high speed train in Indonesia, even new infrastructure will be built to accommodate “high speed train Jakarta-Bandung” by Indonesian Government. Cisomang Railway Bridge is one of existing bridges located in Jakarta-Bandung Line. It is interesting to evaluate whether high speed trains are able to go through the existing Cisomang Railway Bridge. The excessive vibration might be happened to the existing Cisomang Railway Bridge which was not designed for high speed train previously. Some works [6 7] have studied the reducing structural responses with the use of TMD. Dynamic responses of Cisomang Railway Bridge will be evaluated, which are structure’s displacement and acceleration. If the structure’s responses exceed the limit, TMD will be used to reduce them. This study aimed to analyse the existing structure’s responses due to high speed train before and after the used of TMD. All variation is made to find which one is the most effective

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.