Abstract

基于拉曼散射测温原理,利用分布式光纤对UPVC(硬脂聚氯乙烯)和铸铁自来水管道进行模拟泄漏点定位实验。首先对采集到的原始Anti-Stokes光信号进行滤波平滑处理,再利用相关系数法对温度检测信号进行分类分析,识别自来水管有无泄漏发生,最后通过选择性阈值法识别出UVPC管以及铸铁管中的泄漏点位置。实验结果表明,该系统运行稳定且能够准确识别自来水管泄漏情况。选择性平均阈值法的使用,能够对200 m的埋地自来水管道准确地进行泄漏点的定位,定位误差为0.25 m~0.65 m。

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.