Abstract

Trying to analysis the influence of the instability of carbide tool materials on cutting temperature measurement by natural thermocouples, a series of experiments calibrating the thermal emf properties of tool inserts were carried out with an improved tool-workpiece thermocouple calibration device. Four chosen types of carbide tools were examined to detect their thermal emf on their different cutting edge areas. By calculating and comparing the thermal emf waving range of them, the thermal emf stability of carbide tools and the temperature measurement error lead by it was evaluated. As the experiments result, the influence was confirmed. The thermal emf variation among the cemented carbide tools was detailed by using certain statistics processing to the experiment data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.