Abstract
<p> The design value for the shear resistance in Eurocode 2 (EC-2) would have one important disadvantage if a minimum was not fixed for reinforced concrete members without transverse reinforcement. That was, in cases without compressive axial force, the shear capacity would be 0 when the longitudinal reinforcement ratio was 0, although these cases would not be possible if the minimum amount of reinforcement indicated in the codes is considered. When the Spanish Code (EHE-08) was edited, the basic formula adopted was the same as the formula defined in EC-2 but the minimum formula was modified. So, the EHE-08 and the EC-2 equations to assess minimum shear strength are inconsistent with one another and in both cases provide a poor fit to experimental findings. This paper summarizes the most important conclusions of an investigation conducted in the Faculty of Civil Engineering at the UPM and incorporates a new proposal.</p>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.