Abstract

This paper take a bolt-ball node network frame factory building collapse in shanxi as the research background,it suddenly had a partial collapse after used 13 years. Based on the field testing,fracture analysis and theoretical calculation with the finite element analysis software ABAQUS and MIDAS,including the simulating of the M33 high streng bolt’s stress concentration factor and the analysis of the grid structure’s force conditions, we found the cause of the high strength bolt’s fatigue fracture ,and finally,we concluded that this was a rare low cycle fatigue destruction under the action of indirect dynamic load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.