Based on the water conductivity of Lu’an coal mine collapse column and the analysis of the causes of water inrush of Lu’an coal mine collapse column, the water inrush source of collapse column in Changcun Mine was comprehensively analyzed by stable isotope tracing method. It was found that the groundwater runoff conditions and geological structure condition of collapse column seriously affected the water inrush of collapse column. It is determined that the water inrush source of N2-7 collapse column in Changcun coal mine is the same as the Upper Sandstone water source, that is, the infiltration supply of atmospheric precipitation, but has no direct connection with the aquifer of Ordovician limestone., which provides a relatively reliable method for the water inrush source identification of collapse column.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.