Abstract

This paper presents a thermal-hydraulic model of the sodium-heated once-through steam generator and its application to analyze the wall temperature jump of China Generation IV SFR Steam Generator (CSSG). Firstly, this model is verified with experimental data and another design code, which proves the reliability of this model. Secondly, the heat transfer characteristics of CSSG is obtained by using this model. Thirdly, the location and magnitude of maximum water wall temperature jump are chosen as figures of merit for the sensitivity analysis for CSSG. Based on numerical calculations and conservative consideration, it is concluded that the sodium inlet temperature and the water inlet mass flow rate must be strictly controlled in the operation of CSSG, and that the maximum water wall temperature jump is set to around 30 °C in the following stress design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.