Abstract

This paper deals with the measurement, modeling, and simulation of very fast transient overvoltages in layer-type distribution transformer windings. Measurements were performed by applying a step impulse with 50-ns rise time on a single-phase test transformer equipped with measuring points along the winding. Voltages along the transformer windings were computed by applying multiconductor transmission-line theory for transformer layers and turns. Interturn voltage analysis has also been performed. Computations are performed by applying an inductance matrix determined in two different ways; by making use of the inverse capacitance matrix and by making use of the well known Maxwell formulas. The modeling of the transformer and the computations are verified by measurements

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.