Abstract

IntroductionDue to complexities in its measurement, adequacy of ventilation is seldom used to categorize disease severity and guide ventilatory strategies. Ventilatory ratio (VR) is a novel index to monitor ventilatory adequacy at the bedside. . is 100 mL.Kg-1.min-1 and is 5 kPa. Physiological analysis shows that VR is influenced by dead space (VD/VT) and CO2 production . Two studies were conducted to explore the physiological properties of VR and assess its use in clinical practice.MethodsBoth studies were conducted in adult mechanically ventilated ICU patients. In Study 1, volumetric capnography was used to estimate daily VD/VT and measure in 48 patients. Simultaneously, ventilatory ratio was calculated using arterial blood gas measurements alongside respiratory and ventilatory variables. This data was used to explore the physiological properties of VR. In Study 2, 224 ventilated patients had daily VR and other respiratory variables, baseline characteristics, and outcome recorded. The database was used to examine the prognostic value of VR.ResultsStudy 1 showed that there was significant positive correlation between VR and VD/VT (modified r = 0.71) and (r = 0.14). The correlation between VR and VD/VT was stronger in mandatory ventilation compared to spontaneous ventilation. Linear regression analysis showed that VD/VT had a greater influence on VR than (standardized regression coefficient 1/1-VD/VT: 0.78, : 0.44). Study 2 showed that VR was significantly higher in non-survivors compared to survivors (1.55 vs. 1.32; P < 0.01). Univariate logistic regression showed that higher VR was associated with mortality (OR 2.3, P < 0.01), this remained the case after adjusting for confounding variables (OR 2.34, P = 0.04).ConclusionsVR is an easy to calculate bedside index of ventilatory adequacy and appears to yield clinically useful information.

Highlights

  • Due to complexities in its measurement, adequacy of ventilation is seldom used to categorize disease severity and guide ventilatory strategies

  • The correlation between Ventilatory ratio (VR) and physiological dead space fraction (VD/VT) was stronger in mandatory ventilation compared to spontaneous ventilation

  • Linear regression analysis showed that VD/VT had a greater influence on VR than V CO2

Read more

Summary

Introduction

Due to complexities in its measurement, adequacy of ventilation is seldom used to categorize disease severity and guide ventilatory strategies. V Epredicted is 100 mL.Kg-1.min-1 and PaCO2ideal is 5 kPa. Physiological analysis shows that VR is influenced by dead space (VD/VT) and CO2 production (V CO2). Physiological dead space fraction (VD/VT) and CO2 production dictate the ventilatory demands of the body. Due to the complexity or equipment costs associated with its calculation, VD/VT is seldom measured in daily intensive care unit (ICU) practice [5,6]. The partial pressure of oxygen in arterial blood/fractional concentration of inspired oxygen (PaO2/FiO2) is a simple ratio that describes the adequacy of oxygenation and is widely used in daily practice despite being a poor predictor of outcome [7]. A similar quick reference tool does not exist for ventilation

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call