Abstract

Cryogenic fluid damper seals operating close to the liquid-vapor region (near the critical point or slightly sub-cooled) are likely to develop a two-phase flow region which affects the seal performance and reliability. An all-liquid, liquid-vapor, and all-vapor, i.e., a “continuous vaporization” bulk flow model is presented for prediction of the seal dynamic forced response. Continuity, momentum, and energy (enthalpy) transport equations govern the two-phase flow of a homogeneous saturated mixture in thermodynamic equilibrium. Static and dynamic force performance characteristics for the seal are obtained from a perturbation analysis of the governing equations. Theoretical predictions and comparisons to experimental measurements in a liquid and gaseous nitrogen seal are presented in Part II. The effects of two-phase flow regimes on the dynamic force coefficients and stability of an oxygen damper seal are also discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.