Abstract

A method for the measurement of parts per billion levels of total arsenic in urine and blood is described. Samples are wet ashed with a mixture of HNO3, HCIO4, and H2SO4 acids. Ashed materials are subjected to a reductillationTM procedure to reduce As (V) to As (III) and to separate arsenic from the sample matrix. Collected arsenic is then quantitated by anodic stripping voltammetry (ASV) at a gold film electrode. ASV analysis time is only 2 minutes. By simultaneous reductillation of 4 samples, ppb arsenic determinations can be accomplished at a rate of about 12 per hour. The method is as accurate, precise and reliable at the nanogram level as the more universally accepted colorimetric techniques are at the microgram and milligram levels. For replicate analysis of real samples, method precision ranged from +/- 1.4 ppb at the 5 ppb level to +/- 0.96 ppb at the 25 ppb level. Accuracy is estimated at +/- 6% over the range 5 to 500 ppb arsenic.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.