Abstract

A rapid and sensitive column-switching semi-micro HPLC method is described for the direct analysis of tofisopam in human serum. The sample (100 microL) was directly injected onto the precolumn (Capcell Pak MF Ph-1), where unretained proteins were eluted to waste. Tofisopam was then eluted into an enrichment column using 13% acetonitrile in 50 mM phosphate buffer (pH 7.0) containing 5 mM sodium octanesulfonate and subsequently into the analytical column using 43% acetonitrile in 0.1% phosphoric acid containing 5 mM sodium octanesulfonate. The detection limit (2 ng/mL), good precision (CV < or = 4.2%) and speed (total analysis time 24 min) of the present method were sufficient for drug monitoring. This method was successfully applied to a bioequivalence test of two commercial tofisopam tablets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.