Abstract

The consequences of sever reactor accident depend greatly on containment safety features and containment performance in retaining radioactive material. The specific type of large LOCA is DECL (Double Ended Cold Leg) break which means a total guillotine type of break in cold leg pipe and is one of the most dangerous accidents in the reactor containment. In this paper, thermal–hydraulic parameters (temperature and pressure) of WWER-1000 (Bushehr Nuclear Power Plant) containment in a DECL accident have been simulated by CONTAIN 2.0 code and a single cell model. The containment has been divided to 23 cells in CONTAIN code but for simplicity only one cell has been considered in modeling. The model has been programmed by MATLAB. The accident has been simulated for a short time (initial 200s) and all of the results have been compared with Bushehr’s Nuclear Power Plant FSAR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.