Abstract
Using pressure diagram to analyze the pressure distribution of distributed power system when the zero-pressure-difference point is in different positions. Conclusions can be drawn as follows: the zero-pressure-difference point should be between the critical point and heat source to eliminate the energy consumption of regulators. And as a result the transmission energy consumption of the system becomes lowest. When the zero-pressure-difference point is in different positions between the critical point and heat source, arrangements of pumps of the system are different. But the total output power of the pumps is the same. The zero-pressure-difference point and the schemes for pump head can be conveniently determined by graphical method like pressure diagram or numerical method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.