Abstract

Abstract A method is presented for the determination of trace volatile organics in landfill gas using automated thermal desorption—gas chromatography—mass spectrometry. The method includes preconcentration of the trace volatiles using sample tubes containing a sandwich of three adsorbents, Tenax TA, Chromosorb 102 and Carbosieve SIII. Breakthrough and recovery measurements were carried out on the sample tubes for landfill gas volumes of up to 1 litre. Breakthrough was not observed on any of the samples taken and recovery for all the components was found to be approximately 100%. Over 125 VOCs were identified in the landfill gas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.