Abstract

The paper presents a measuring system based on two resonators with a SAWacoustic surface wave. One of the resonators contains a sensor structure consisting of a Nafion layer with a PANI polyaniline nanolayer deposited on it. The sensor structure was tested for carbon monoxide, with a very low concentration (5, 10, 15, 20 ppm) in the atmosphere of synthetic air. The structure sensitivity was tested for two different PANI thicknesses: (100 and 180 nm). The tests were carried out for two different temperatures: 308 K and 315 K. The investigations shows that the measuring system used with the acoustic surface wave together with the proposed sensing layers is sensitive to the presence of low concentration carbon monoxide molecules in the atmosphere of synthetic air.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.