Abstract

A study was carried out in order to evaluate the possible problems linked to spot welding of galvanized steel plates and high-strength austenitic stainless steels (AISI 301). Testpieces were made by joining two edges of galvanized plate by an AISI 301 steel plate. These testpieces were loaded at approx. 50% of σ0.2 of the stainless steel. Two steels of the same type but of different origin and supply were used: the first (steel A) was sensitised and sometimes failed, even after a few days; the second (steel B) was solution-treated and did not fail. Besides the fracture morphologies, the microstructures of the two stainless steels, the welding defects and the presence in the steels of hydrogen from the galvanized plate during fusion of the spot weld were discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.