Abstract

From the performance analysis of the anaerobic digestion system at the Regina Wastewater Treatment Plant, it was found that the anaerobic digestion system at the Regina plant was generally operated in a stable condition as indicated by pH, volatile acids and alkalinity levels. The operation of the anaerobic digestion system was not optimal because of the low volatile solids concentration and low volatile solids loading rate, especially because of high HRT. Two options, thickening the primary sludge and increasing the volatile solids loading rate, were recommended for the optimal operation of the digestion system. After examining a number of kinetic models, it was found that the Chen–Hashimoto model could be used to predict the volumetric methane production rate and the first-order model could be used to predict the efficiency of volatile solids reduction. The study showed that utilization of digester gas for power production was the best alternative for the excess digester gas. 13.3% of the electrical demand and 35.5% of the plant's total energy could be met based on digester gas wasted, assuming 25% as the conversion efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.