Abstract
The report analyzes the work of a pumping unit from the hot water installation of the Faculty of Technics and Technologies - Yambol, Bulgaria, under different load conditions. Simulation stands have been adapted that are suitable for analyzing the performance of motors of different types and depending on how they are put into the pump unit. It was found that when the energy inefficient electric motor is directly started, the maximum efficiency is 79,63% and is achieved at 100% of its load. When using a frequency converter, at 100% of its load, the efficiency is 86,83%. The proposed energy-efficient electric motor, with direct start-up, has the highest efficiency of 86,7%. The obtained results can be used in the modernization of the hot water installation of the Faculty of technics and Technologies - Yambol, in the part “pumping units”.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Conference on Technics, Technologies and Education
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.