Abstract

A high performance liquid chromatographic (HPLC) procedure was developed for the analysis of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid in urine. Hydrolyzed urine samples were cleaned up using Bond-Elut columns. 11-Nor-cannabinol-9-carboxylic acid was used as internal standard. The analysis was carried out using a C8 reversed-phase column with acetonitrile:50 mM phosphoric acid (65:35) as the solvent. Detection was done by ultraviolet detector at 214 nm. The minimum detectable level of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid was 25 ng/mL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.