Abstract

This article through to the two common cast-in-situ frame structure (casting of a whole, with a construction joint) and 6 root not construction joints under axial pressure ratio through concrete columns of different processing low reversed cyclic loading experiment, study their experimental phenomena, hysteresis curves, displacement ductility, stiffness degradation, thus draw the conclusion: 1, the existence of the construction joint can lead to the decline of ductility of frame structure. 2. When the test axial pressure is relatively low, the presence or absence of construction joints and different treatment methods will obviously affect the ductility of the cast-in-place frame structure. 3. When the test axial pressure is relatively high, the presence or absence of construction joints and different treatment methods will not have a significant impact on the ductility of the cast-in-place frame structure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.