Abstract
A combined system of anaerobic–aerobic techniques was used for deep co-treatment of mature landfill leachate and domestic sewage, mixed at a ratio of 1:5, through partial nitrification–anammox. While ensuring synchronous removal of organic matter and nitrogen, we investigated changes in several factors under different reflux ratios (0%, 100% and 300%). High nitrification efficiency and a relatively high accumulation rate of NO2−-N were achieved, the latter through selective inhibition of bacteria by free ammonia. The results indicated that maintaining the reflux ratio within an optimum range contributes to the enrichment of anammox bacteria. In this study, the optimum ratio, which permitted the highest removal rates of chemical oxygen demand (COD), NH4+-N, and total nitrogen, was 300%. The COD level in the anammox reactor (ANAOR) decreased to lower than 70mg/L, resulting in no inhibitory effect on anammox and maximum enrichment of bacteria.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.