Abstract

The development of effective diagnostic kits for HIV-1 remains a pressing concern. We designed diagnostic oligonucleotides for HIV-1 real-time PCR to target the most conserved region of the HIV-1 genome and assessed the mutation frequency at annealing sites. Two databases of nucleotide sequences, Los Alamos and NCBI, were analyzed, revealing that more than 99% of the sequences either lack mutations or contain 1-2 mutations at the binding site of the forward and reverse primers. Additionally, 98.5% of the sequences either lack mutations or contain 1-2 mutations at the binding site of the TaqMan probe. To evaluate the efficiency of primers and the probe in real-time PCR in the case of mutations at their binding sites, we constructed several plasmids containing the most common mutations and, in a model experiment, showed how different mutations affect the efficiency of PCR. Our analysis demonstrated that about 98.5% of HIV-1 strains can be efficiently detected using a single pair of selected primers. For the remaining 1.5% of strains, a more careful selection of the second target is needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.