The paper investigates the flow noises caused by the high temperature liquid Sodium in the nuclear main pump system. Three-dimensional unsteady CFD coupled sound field methods are exploited. Spectrum characteristics of sound source load are obtained. Directional sound pressure level distribution based on sound source load of rotor blades and guide vanes are presented and discussed. Distribution of sound pressure level of inlet and outlet pipes along the flow direction are also further discussed. Results indicate that with the increase of blade passing frequency, the amplitude of sound pressure level decreases. Response of sound field mainly depends on the load characteristics of rotor blades. Research results have remarkable significances for the analysis of flow noises in liquid Sodium pump systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.