One of the primary methods to produce medical isotopes, such as 99Mo, is by irradiation of uranium targets in heterogeneous reactors. Solution reactors present a potential alternative to produce medical isotopes. The Medical Isotope Production Reactor (MIPR) concept has been proposed to produce medical isotopes with lower uranium consumption and waste than those in heterogeneous reactors. Commercial production of medical isotopes in solution reactors requires steady-state operation at ~200 kW. At this power regime, fuel-solution temperature increase and radiolytic-gas bubble formation introduce a negative reactivity feedback that has to be mitigated. A model based on the point reactor kinetic equations has been developed to investigate these reactivity effects. This model has been validated against experimental results from the Los Alamos National Laboratory uranyl fluoride Solution High-Energy Burst Assembly (SHEBA) and shows the feasibility of solution reactors for the commercial production of medical isotopes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.