Abstract

A method for analyzing the influence of velocity changes on metal signals of different materials in oil detection technology is proposed. The flow rate of metal contaminants in the oil will have a certain impact on the sensitivity of the output particle signal in terms of electromagnetic fields and circuits. The detection velocity is not only related to the sensitivity of the output particle signal, but also to the adaptability of high-speed and high-throughput in oil online monitoring. In this paper, based on a high-sensitivity inductive bridge, the eddy current effect of velocity in a time-harmonic magnetic field is theoretically analyzed and experimentally verified, the phenomenon of particle signal variation with velocity for different materials is analyzed and discussed, and finally the effect of velocity on the output signal of the processing circuit is also elaborated and experimentally verified. Experiments show that under the influence of the time-harmonic magnetic field, the increase of the velocity enhances the detection sensitivity of non-ferromagnetic metal particles and weakens the detection sensitivity of non-ferromagnetic particles. Under the influence of the processing circuit, different velocities will produce different signal gains, which will affect the stability of the signal at different velocities.