Abstract

This paper presents an experimental technique to characterize the damage evolution of the topside interconnections of power semi-conductor devices during power cycling tests. DC power cycling tests are done on Semikron SKIM 63 power modules, a solder-free module with silver sintered chips, ensuring the degradations to appear in the top layers only. The cycled substrates are then extracted from the test bench at different steps of the aging for analysis. Four-probe measurements are implemented on the chips so that the evolution of physical parameters representative of the degradation in the metallization and the bond wire contacts can be obtained. Finally, optical microscopy analysis of cross-sections at the wire bond contact interface is carried out to corroborate the electrical measurements to the crack length growth after specific aging intervals.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.