Abstract

A general expression for the spectrum of the DC-link current of single- and three-phase voltage source inverters is presented to predict the amplitude and frequency of the harmonic components produced by balanced and unbalanced loads, defining positive, negative and zero sequence components. The computation is developed using the switching functions approach, relating the output voltage waveform to the absorbed DC-link current; so, the method may be applied also to measured waveforms, when no analytical expression is available. The method is extended also to the general case of nonsinusoidal load currents. The spectrum of the DC-link current for several inverter modulations (deterministic and random modulations) is calculated and considerations on the harmonic distortion and DC-link filter requirements are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.