Abstract
The corium containing stainless steel, partially oxidized zirconium cladding and fuel materials in the lower plenum may separate into immiscible liquids at high temperatures that influence the heat flux into vessel during in-vessel melt retention (IVR). In this work, the stratification of the corium in the lower plenum and the distribution of heat flux on the outside of vessel for AP1000 were assessed by three well-accepted 3-layer models developed by Esmaili & Khatib-Rahbar (model 1), Seiler (model 2), Salay & Fichot (model 3) respectively. In addition, the heat transfer in the corium is analyzed for a typical 1000 MWe Advanced PWR in China after a hypothetical station blackout accident. The results shown that the maximum heat flux of corium pool obtained by model 1 and 2 are both smaller than the CHF of AP600. Although it is slightly larger in model 2, enough safety margin is still retained compared with the CHF of AP1000.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.