Abstract

AbstractA mathematical model based on fluid dynamics and heat‐transfer theories was applied to predict gas dynamic pressure and temperature distribution in a coflow molten carbonate fuel cell (MCFC) stack. The mass balance was simplified to obtain exact solutions with an assumption of uniform current density in the cell. The simulations were compared with data from a pilot‐scale MCFC stack. The effect of internal geometry of gas channels was simulated to accurately predict the gas‐pressure drop. A close prediction of pressure drop was possible from a partially blocked gas channel model that approximates the significant flow resistance. The effect of external boundary conditions on stack temperature profile was also analyzed. Temperatures were accurately predicted from a boundary heat conduction model with a reasonable assumption of wet seal temperatures. The 2‐D boundary conditions could be extended to 3‐D simulations to predict temperature distribution with the same accuracy. The model was applied to see the effect of scale‐up on the maximum temperature rise and average cell potential. The result verified a significant effect of cell size on the maximum stack temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.