Abstract
Accurately estimation the location and degree of structural damage is the key to verify the effectiveness of structural damage detection methods. The natural frequency and curvature mode are chosen as the damage detection indexes, and the availability of indexes is tested by setting different damage scenarios on simply supported beam. The results show that the natural frequency index can identify the location of a single damage, but the damage degrees fail to be estimated. The curvature mode obtained from the low-order mode is able to effectively identify the damage location in damage scenarios, and can reflect the damage degree.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.