Abstract

The interface friction coefficient is an important design parameter for reinforced soil structures where the friction between the soil and reinforcement elements is mobilized. The pull-out test is the most commonly adopted method to identify this friction coefficient. In this paper, 18 pull-out tests were conducted on two types of welded steel meshes (normal and dense mesh) embedded in a sand to investigate the soil/reinforcement interaction. The tests were conducted under vertical stresses ranging from 20 to 140 kPa on the reinforcement. The French standard (NF P 94-270, 2009) uses an analytical method to predict the friction coefficient. The comparison with the experimental results agrees reasonably well. Ju et al. (2004) developed a new test method based on a staged pull-out test for extensible reinforcements. In this study and for inextensible reinforcement, this new test method has also been used. In a usual pull-out test, only one vertical stress has been used. For a staged pull-out test, several vertical stresses are used. The results of staged pull-out tests are in good agreement with results of usual pull-out test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.