The lack of detailed knowledge about the interaction of the velocity field and suspended sludge poses an obstacle in designing more effective sedimentation tanks. This study investigates the use of CFD analysis of hydraulic processes and the influence of seasonal temperature change on a waste water treatment sedimentation tank. The object analysed in this pilot research is a part of the WWTP in Nitra-Dolne Krskany, SK. The analysis was conducted using the CFD model ANSYS Fluent®, supported by field measurement data, which was gathered on two separate occasions in July 2015 and February 2016 at the sedimentation tank during operation. Three parameters were collected in 400 measurement points throughout the tank. During the research we analysed the data, looking for correlation with the CFD simulation to verify the results and correlations between the winter and summer period to determine the influence of varying temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.