Abstract

BackgroundFacial features are regarded as representative and reliable characteristics for diagnosing a person's Sasang Constitution (SC). However, the description of these features tends to depend on the interpretation and the opinion of the doctor that follows the SC approach. In this paper, we performed a facial feature analysis of SC types in an objective and quantitative manner. Here, site-to-site variability can be an obstacle to properly analyzing facial features when images are taken from various sites, which may have different experimental environments. A compensation technique to reduce the site-to-site variability was proposed before performing the feature analysis. MethodsThe frontal and profile images of 1464 patients recruited from various oriental medical clinics (19 sites) were used. Candidate feature variables were created, which were inspired by the facial characteristics of the SC types described in the Sasang constitutional medicine literature. To resolve the problems involved in processing data collected from various sites with heterogeneous experimental environments, a compensation technique was proposed. Statistical analysis techniques were employed to observe the differences among the SC types and to demonstrate how effectively the site-to-site variability was reduced. ResultsThe facial features that were significant for diagnosing the SC types were identified by a statistical analysis, and it was verified that the compensation technique reduced the site-to-site variability produced by the differences in photographic distance. ConclusionIt is noted that the significant facial features represent common characteristics of each SC type in the sense that we collected extensive opinions from many Sasang constitutional medicine doctors with various points of view. Additionally, a compensation method for the photographic distance is needed to find the significant facial features. We expect these findings and the related compensation technique to contribute to establishing a scientific basis for the precise diagnosis of SC types in clinical practice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.