Analysis of reverse osmosis membrane performance during desalination of simulated brackish surface waters

  • Abstract
  • Literature Map
  • Similar Papers
Abstract
Translate article icon Translate Article Star icon

Analysis of reverse osmosis membrane performance during desalination of simulated brackish surface waters

Similar Papers
  • PDF Download Icon
  • Research Article
  • Cite Count Icon 14
  • 10.3390/membranes7020023
Foulant Analysis of Three RO Membranes Used in Treating Simulated Brackish Water of the Iraqi Marshes
  • Apr 13, 2017
  • Membranes
  • Dawood Eisa Sachit + 1 more

In this work, three different types of Reverse Osmosis (RO) (Thin-Film Composite (SE), Cellulose Acetate (CE), and Polyamide (AD)) were used to perform foulant analysis (autopsy) study on the deposited materials from three different simulated brackish surface feed waters. The brackish surface water qualities represented the water quality in Iraqi marshes. The main foulants from the simulated feed waters were characterized by using Scanning Electron Microscope (SEM) images and Energy-Dispersive X-ray Spectroscopy (EDXS) spectra. The effect of feed water temperatures (37 °C and 11 °C) on the formation of the fouled material deposited on the membrane surface was examined in this study. Also, pretreatment by a 0.1 micron microfiltration (MF) membrane of the simulated feed water in advance of the RO membrane on the precipitated material on the membrane surface was investigated. Finally, Fourier Transform Infrared Spectroscopy (FTIR) analysis was used to identify the functional groups of the organic matter deposited on the RO membrane surfaces. The SEM images and EDSX spectra suggested that the fouled material was mainly organic matter, and the major crystal deposited on the RO membrane was calcium carbonate (CaCO3). The FTIR spectra of the fouled RO membranes suggested that the constituents of the fouled material included aliphatic and aromatic compounds.

  • Conference Article
  • Cite Count Icon 2
  • 10.5339/qfarc.2016.eepp2725
Will Reverse Osmosis Replace Thermal Desalination in GCC Region
  • Jan 1, 2016
  • Adel Obaid Sharif

Desalination is probably the only means for fresh water supply to countries in decertified climate. The majority of GCC counties rely on desalinated water for fresh water supply to major cities. Over 70% of the desalinated water in the GCC comes from thermal desalination plants including Multi Stage Flash (MSF) and Multi Effect Distillation (MED). The new trend in the desalination plant in the GCC is 30% Reverse Osmosis (RO) and 70% thermal. However, these percentages vary from one to another country depending on feed water quality and expertise. For example, Oman Sea has lower salinity than the Gulf water and hence Oman uses more RO for desalination than MED and MSF. This decision is also driven by economy as RO process less energy intensive and hence the produced water is less expensive as compared to thermal plants. On the contrary, Qatar and Kuwait use more MSF followed by MED due to the high salinity and low quality feed water. This is also because trials of RO in both Qatar and Kuwait were not successful because of the problems of membrane fouling and restrict pre-treatment requirements due to the quality of the water intake.The advantages of RO over thermal technologies are well known in terms of lower energy consumption and the cost of produced water; but are not yet taken advantage of in the GCC zone. One of the reasons is blamed on high feed water salinity and bad water quality; other reasons such as lack of experience, red tides and reliability are contributed to the dominance of thermal plants. However, field experience showed that good pretreatment and optimized RO design may overcome the problems of high feed salinity and bad water quality. Several RO plants, such as Fujairah in UAE, are good examples of a working RO technology in the harsh water environment. Good RO design includes design and optimization of both pretreatment and post-treatment. Field experience showed that most of RO plants failure was due to inefficient pretreatment which resulted in providing low quality water to the RO membrane that caused fouling. Fouling, including biological and scaling, can be handled once an efficient pretreatment process is available. Recent advances in pre-treatment techniques include the combination of Forward Osmosis (FO) with RO among other methods. Recent studies by the authors including commercial implantations have shown that the combination of FO with RO addresses the most technical challenge of RO process and that is fouling, which results in lower energy consumption and less chemical additives. Experience showed fouling in FO process in reversible, i.e. can be removed by backlashing while fouling in conventional RO process is irreversible.In this study, the feasibility of integrating FO with RO process for the desalting of the Gulf water in Qatar is presented. The results are expressed in terms of specific energy consumption, process recovery, produced water quality, chemical additives and overall process cost.The implementation of RO for desalination is not only reducing the cost of desalination but also the environmental impact. More R&D should be done to provide useful data about RO application and suitability for the Gulf water. The R&D should be focused on laboratory to market development of RO technology using rigorous lab scale and pilot plant testing program.

  • Research Article
  • Cite Count Icon 46
  • 10.1016/j.desal.2012.06.011
Advanced characterization of organic foulants of ultrafiltration and reverse osmosis from water reclamation
  • Jun 30, 2012
  • Desalination
  • Kangmin Chon + 3 more

Advanced characterization of organic foulants of ultrafiltration and reverse osmosis from water reclamation

  • Research Article
  • Cite Count Icon 17
  • 10.1002/wer.10717
A hybrid process for leachate wastewater treatment: Evaporation and reverse osmosis/sequencing batch reactor.
  • Apr 1, 2022
  • Water environment research : a research publication of the Water Environment Federation
  • Raouf Bouchareb + 5 more

In this study, a hybrid process for leachate wastewater treatment including evaporation and reverse osmosis (RO) membrane or biological treatment systems was suggested. Experiments were performed on a real landfill leachate wastewater. The leachate was subjected to evaporation; as a result, a distillate was obtained containing less organic matter and less substantial amounts of other pollutants, as ammonium salts and total phenols were removed. Tests were carried out at different evaporation temperatures and times. The initial leachate pH was adjusted and optimized. For optimum conditions, each of chemical oxygen demand (COD), total phenol, and ammonium salt concentrations were reduced to 99.99%, 95.00%, and 83.00%, respectively. The distillate of the first stage of the proposed process was then exposed to RO membrane system, as a first study, under different transmembrane pressure of 20, 30, and 40 bar and at different pH values of 7, 8, and 9. As a second suggested treatment system, the distillate was subjected to a biological treatment process for 30 days as a retention time, pH = 6, and room temperature 25°C ± 1°C. At the end of the research study, a comparison was conducted between results obtained with RO membrane separation and biological treatment system as two distinct treatment systems proposed for leachate landfill wastewater treatment. Although both systems were effective for landfill leachate wastewater treatment, however, with the RO membrane separation system, COD removal efficiency reached 99.99%. In the other hand, with biological treatment process, COD elimination was as much as 90.00%. Certainly, evaporation and RO are not novel ways of landfill leachate treatment; however, few studies have attempted to use similar combined system for landfill leachate wastewater treatment and attained effective results of treated water. PRACTITIONER POINTS: A hybrid process of evaporation and RO membrane or biological treatment systems was suggested for leachate wastewater treatment. For optimum conditions, COD, total phenols, and ammonium salt reductions were achieved to 99.99%, 95%, and 83%, respectively, after the first evaporation stage. The distillate of the first stage of the proposed process was then exposed to RO membrane system and biological treatment system. Different transmembrane pressure and different pH values were optimized for RO.

  • PDF Download Icon
  • Conference Article
  • 10.5339/qfarc.2018.eepd1080
Characterization of Commercial Reverse Osmosis and Nanofiltration Membranes for Membrane Fouling
  • Jan 1, 2018
  • Mohammad Yousaf Ashfaq + 3 more

Membrane Filtration technique is being accepted worldwide as an environment friendly and energy efficient technique in Desalination Industry as compared to Thermal Desalination techniques. However, the performance of membranes which include permeate flux and rejection is affected by the membrane fouling. The properties of membrane and surface features such as porous structure, hydrophilicity/hydrophobicity charge, polymer characteristics, surface roughness determine the fouling potential of the membrane. The hydrophilic and smooth membrane surface is usually considered desirable in tackling membrane fouling issues. Therefore, many studies have focused on to enhance surface characteristics of membranes by surface coating with polymers and nanomaterials. Since, membrane coating is not done during fabrication of the most commercially available membranes, therefore, it is also important to determine the surface features of the commercially available membranes to investigate their membrane fouling potential. Thus, the objectives of this study were (1) to perform membrane surface characterization of commercial Reverse Osmosis (RO) and Nanofiltration (NF) membranes using techniques such as SEM, AFM, FTIR and XPS; (2) to measure hydrophilicity/hydrophobicity of commercial RO and NF membranes through water contact angle measurement using sessile drop method and (3) to measure the flux and percentage rejection of NF and RO membranes using Dead end filtration technique. Here, the characterization of membrane surface in terms of surface roughness, using SEM and AFM, showed that the commercial RO membrane had more ridge and valley structures and higher average surface roughness i.e. 71.24 nm as compared to NF membranes (6.63 nm). In addition, water contact angle measurements showed that the NF membrane was more hydrophilic as compared to RO membrane. The average contact angle found for RO membrane was 59.94°. On the other hand, it was observed that NF membrane is extremely hydrophilic in nature. Due to which, contact angle value was not obtained for most of the runs. The droplet could diffuse in less than 5 seconds. In addition, the dead-end filtration experiments showed that the RO membrane had much lower flux as compared to NF membrane. This can be associated with the pore structure of these membranes. Since, the NF membrane has porous structure, in oppose to RO membrane, the flux of the NF membrane is usually higher than the RO membranes. As the membrane surface roughness and hydrophobicity makes it more susceptible to the fouling leading to reduction in membrane flux and performance, it can be concluded from this study that there is a need for surface coating of RO membrane with suitable nanomaterials such as graphene oxide to improve its hydrophilicity and surface smoothness. This will eventually make the membrane more resistant to membrane fouling and will establish the use of membrane filtration technique in desalination industry in Qatar in the future. Microorganisms have been isolated from Gulf sea water, identified and differentiated and are being used to study the biofouling of RO and NF membranes, that would be coated to limit the fouling problems. Acknowledgement: This research was made possible by NPRP grant # [9-318-1-064] from the Qatar National Research Fund (a member of Qatar Foundation). The findings achieved herein are solely the responsibility of the author[s].

  • Research Article
  • Cite Count Icon 3
  • 10.2166/aqua.2023.217
Efficacy testing of non-oxidizing biocides for polyamide membrane biofouling prevention using a modified CDC biofilm reactor
  • Feb 20, 2023
  • Journal of Water Supply: Research and Technology-Aqua
  • Luiz H Da-Silva-Correa + 5 more

Biofouling is one of the most challenging obstacles faced by reverse osmosis (RO) membrane systems to supply potable water. Currently, biofouling is imperfectly handled by RO feed water pre-chlorination, which is associated with the production of carcinogenic disinfection by-products. To propose a safer alternative to control biofouling in RO drinking water applications, this study investigates the efficacy of five biocides to prevent and remove Pseudomonas aeruginosa biofilms from RO membranes: 2-methyl-4-isothiazolin-3-one (MIT); 2,2-dibromo-3-nitrilopropionamide (DBNPA); sodium bisulfite (SBS); sodium benzoate (SB); and ethyl lauroyl arginate (LAE). Experiments were conducted on the Center for Disease Control (CDC) Biofilm Reactor (CBR) with biocidal dosing estimated on 96-well microtiter plates. Confocal Scanning Laser Microscopy (CLSM) and Scanning Electron Microscopy (SEM) were used to analyze the biocides' anti-biofilm efficacies under dynamic conditions relative to minimum biofilm inhibitory and eradication concentrations. The results in this study indicated that LAE presented the best anti-biofilm efficacies in treating P. aeruginosa biofilms when compared to all studied biocides; it not only prevented biofilm formation (>98%) but also it effectively removed pre-established biofilms (>99%) from RO membrane coupons. Therefore, due to safety and efficacy, LAE is an excellent candidate for controlling biofouling in drinking water RO membrane systems.

  • Research Article
  • Cite Count Icon 2
  • 10.2166/wpt.2009.068
High Performance RO Membranes for Desalination and Wastewater Reclamation and Their Operation Results
  • Dec 1, 2009
  • Water Practice and Technology
  • M Henmi + 3 more

Reverse osmosis (RO) membrane is one of the most powerful tools for solving the global water crisis, and is used in a variety of water treatment scenes such as drinking water purification, waste-water treatment, boiler feed water production, ultra pure water production for semiconductor industry, etc. The desired performance of RO membrane varies according to quality of feed water being treated, and Toray has been developing RO membranes with suitable characteristic for each operating condition. RO membranes for seawater desalination and wastewater reclamation are especially regarded as most promising targets. Recently, high boron removal and energy saving RO membrane for seawater desalination and low fouling RO membrane for wastewater reclamation have been developed. In this paper, the prospect of attaining these renovative RO membrane, and furthermore, job references will be discussed.

  • Research Article
  • Cite Count Icon 36
  • 10.2166/wst.2010.396
High performance RO membranes for desalination and wastewater reclamation and their operation results
  • Nov 1, 2010
  • Water Science and Technology
  • M Henmi + 3 more

Reverse osmosis (RO) membrane is one of the most powerful tools for solving the global water crisis, and is used in a variety of water treatment scenes such as drinking water purification, waste-water treatment, boiler feed water production, ultra pure water production for semiconductor industry, etc. The desired performance of RO membrane varies according to quality of feed water being treated, and Toray has been developing RO membranes with suitable characteristic for each operating condition. RO membranes for seawater desalination and wastewater reclamation are especially regarded as most promising targets. Recently, high boron removal and energy saving RO membrane for seawater desalination and low fouling RO membrane for wastewater reclamation have been developed. In this paper, the prospect of attaining these renovative RO membrane, and furthermore, job references will be discussed.

  • Research Article
  • Cite Count Icon 38
  • 10.3390/membranes11050338
Correlations for Concentration Polarization and Pressure Drop in Spacer-Filled RO Membrane Modules Based on CFD Simulations
  • May 1, 2021
  • Membranes
  • Boram Gu + 2 more

Empirical correlations for mass transfer coefficient and friction factor are often used in process models for reverse osmosis (RO) membrane systems. These usually involve four dimensionless groups, namely Reynolds number (Re), Sherwood number (Sh), friction factor (f), and Schmidt number (Sc), with the associated coefficients and exponents being obtained by fitting to experimental data. However, the range of geometric and operating conditions covered by the experiments is often limited. In this study, new dimensionless correlations for concentration polarization (CP) modulus and friction factor are presented, which are obtained by dimensional analysis and using simulation data from computational fluid dynamics (CFD). Two-dimensional CFD simulations are performed on three configurations of spacer-filled channels with 76 combinations of operating and geometric conditions for each configuration, covering a broad range of conditions encountered in RO membrane systems. Results obtained with the new correlations are compared with those from existing correlations in the literature. There is good consistency in the predicted CP with mean discrepancies less than 6%, but larger discrepancies for pressure gradient are found among the various friction factor correlations. Furthermore, the new correlations are implemented in a process model with six spiral wound modules in series and the predicted recovery, pressure drop, and specific energy consumption are compared with a reference case obtained by ROSA (Reverse Osmosis System Analysis, The Dow Chemical Company). Differences in predicted recovery and pressure drop are up to 5% and 83%, respectively, highlighting the need for careful selection of correlations when using predictive models in process design. Compared to existing mass transfer correlations, a distinct advantage of our correlations for CP modulus is that they can be directly used to estimate the impact of permeate flux on CP at a membrane surface without having to resort to the film theory.

  • Research Article
  • Cite Count Icon 102
  • 10.1016/j.watres.2011.12.062
Combined coagulation-disk filtration process as a pretreatment of ultrafiltration and reverse osmosis membrane for wastewater reclamation: An autopsy study of a pilot plant
  • Jan 14, 2012
  • Water Research
  • Kangmin Chon + 3 more

Combined coagulation-disk filtration process as a pretreatment of ultrafiltration and reverse osmosis membrane for wastewater reclamation: An autopsy study of a pilot plant

  • Research Article
  • Cite Count Icon 14
  • 10.1080/01496390802634414
Analysis of High Recovery Brackish Water Desalination Processes using Fuel Cells
  • Feb 3, 2009
  • Separation Science and Technology
  • Rajindar Singh

The production and supply of potable water and the disposal of wastewater are among the major challenges of the 21st century. Inadequate supply of potable water, coupled with increasing water demand in developing countries due to rapid population growth and industrialization are among the major reasons for the worsening water situation (1). Desalination of brackish water by reverse osmosis (RO) and nanofiltration (NF) are the leading technologies used in supplying potable water. Typically, these plants operate at 75% product water recovery so that 25% of RO feed water is wasted as concentrated brine. However, the recovery can be increased by processing the primary RO reject water with the aid of selective membrane processes such as a secondary RO or NF unit. Hybrid RO/NF processes were modeled using the membrane manufacturer's software for various membranes and for two specific brackish waters studied (total dissolved solids, TDS = 1700 and 3700 mg/1). The analyses show that 90% product water recovery is achieved for the low TDS feed water and 88% recovery is achieved for the high TDS feed water using simple, state-of-the-art hybrid membrane systems, and with minimal feed water chemical pre-treatment. It is also shown that the specific energy consumption of the RO system is reduced when it is powered by a stand-alone, on-site fuel cell power plant.

  • Research Article
  • Cite Count Icon 10
  • 10.1016/j.biortech.2014.08.107
Characterization of membrane foulants in a pilot-scale tunnel construction wastewater treatment process
  • Aug 30, 2014
  • Bioresource Technology
  • Jae-Hyun Lee + 5 more

Characterization of membrane foulants in a pilot-scale tunnel construction wastewater treatment process

  • Research Article
  • Cite Count Icon 26
  • 10.1080/19443994.2012.704696
Cesium (Cs) and strontium (Sr) removal as model materials in radioactive water by advanced reverse osmosis membrane
  • Feb 1, 2013
  • Desalination and Water Treatment
  • Takao Sasaki + 4 more

Cesium (Cs) and strontium (Sr) removal as model materials in radioactive water by advanced reverse osmosis membrane

  • Research Article
  • Cite Count Icon 103
  • 10.1038/s41545-022-00183-0
Reverse osmosis membrane biofouling: causes, consequences and countermeasures
  • Sep 15, 2022
  • npj Clean Water
  • Eric M V Hoek + 2 more

Biofouling has been referred to as “the Achilles heel” of reverse osmosis (RO) membrane technology; the main cause being polyamide RO membranes lack of chlorine tolerance. Biofouling increases the operating cost of water treatment by increasing RO system feed pressure (i.e., energy demand) and increasing membrane cleaning frequency, which increases downtime and reduces membrane useful life. For waters with known high biofouling potential, plant designs also may require more extensive pretreatment, which increases capital and operating costs as well as the footprint of a desalination plant. It is known from the literature that the three keys to fending off biofouling in RO systems and/or recovering from biofouling once it takes root include (1) understanding site-specific processes governing biofilm formation, (2) implementing effective biofouling pretreatment ahead of RO membranes, and (3) monitoring biofouling to enable more proactive and effective RO membrane cleaning. Herein, we present four case studies of RO membrane biofouling in seawater, municipal wastewater, brackish groundwater and industrial wastewater. Next, we describe what is known about the causes and consequences of bacterial biofilm formation and growth through a process level RO membrane biofouling model. Finally, we review common biofouling control methods including pre-treatment, chemical cleaning and the most common strategies for monitoring biofouling in RO membrane systems.

  • Research Article
  • Cite Count Icon 34
  • 10.1016/j.chemosphere.2014.05.042
The role of a combined coagulation and disk filtration process as a pre-treatment to microfiltration and reverse osmosis membranes in a municipal wastewater pilot plant
  • Jun 13, 2014
  • Chemosphere
  • Kangmin Chon + 3 more

The role of a combined coagulation and disk filtration process as a pre-treatment to microfiltration and reverse osmosis membranes in a municipal wastewater pilot plant

Save Icon
Up Arrow
Open/Close