Abstract

For pulse train (PT) controlled switching converter, when it operates in continuous conduction mode (CCM) and discontinuous conduction mode (DCM), there exist disadvantages of low frequency oscillation and narrow load range, respectively. To avoid these disadvantages of PT controlled switching converter in CCM and DCM, a PT controlled boost converter operating in pseudo continuous conduction mode (PCCM) is taken as the research object in this paper, its working principle has been analyzed in detail. Based on the analysis of output voltage ripple during one switching cycle, the combination of high- and low-power control pulses in a repetition cycle is analyzed and the expression of output voltage ripple is derived for different load conditions. Finally, simulation and experiment are performed to verify the correctness of the control pulse combinations and the output voltage ripple analysis. Results show that compared with DCM and CCM boost converters, the PT controlled PCCM boost converter not only has wider load range, but also can suppress low frequency oscillation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call