Abstract

BackgroundThe aqueous humor (AH), a liquid of the anterior and posterior chamber of the eye, comprises many proteins with various roles and important biological functions. Many of these proteins have not been identified yet and their functions in AH are still unknown. Recently, our laboratory published the protein database of AH obtained from healthy rabbits which expanded known protein identifications by 65%. Our present study extends our previous work and analyses AH following two types of cataract surgery incision procedures (clear corneal and limbal incisions) by using two dimensional gel electrophoresis (2-DE) and liquid chromatography tandem mass spectrometry (LC-MS/MS). Although both incision protocols are commonly used during cataract surgeries, the difference in protein composition and their release into AH following each surgery has never been systematically compared and remains unclear. The first step, which is the focus of this work, is to assess the scale of the protein change, at which time does maximum release occurs and when possible, to identify protein changes.ResultsSamples of AH obtained prior to surgery and at different time points (0.5, 2, 12, 24 and 48 hours) following surgery (n = 3/protocol) underwent protein concentration determination, 2-DE and LC-MS/MS. There was a large (9.7 to 31.2 mg/mL) and rapid (~0.5 hour) influx of proteins into AH following either incision with a return to baseline quantities after 12 hours and 24 hours for clear corneal and limbal incision, respectively. We identified 80 non-redundant proteins, and compared to our previous study on healthy AH, 67.5% of proteins were found to be surgery-specific. In addition, 51% of those proteins have been found either in clear corneal (20%) or limbal incision (31%) samples.ConclusionsOur results imply that a mechanism of protein release into AH after surgery is a global response to the surgery rather than increase in amount of protective proteins found in healthy AH and a mechanism of protein release for each type of incision procedure could be different. Although the total protein concentration was increased (at 0.5 and 2 hour time points and between types of surgery) many of 2-DE protein spots were similar based on 2-DE and MS analyses, and only a small number of protein spots changed with either the time points or surgical conditions (0.4 -1.9%). This suggests that the high protein content is due to an increase in the concentration of the same proteins with only a few unique proteins being altered per time point and with the different surgery type. This is the first report on the comparison of AH protein composition following two different cataract surgery procedures and it establishes the basis for better understanding of protein release into AH during events such as cataract surgery or other possible intervention to the eyes.

Highlights

  • The aqueous humor (AH), a liquid of the anterior and posterior chamber of the eye, comprises many proteins with various roles and important biological functions

  • The same experiments could not be performed at high protein load for AH samples with low protein concentration (pre-surgery samples, and samples at time points 12, 24 and 48 hours for clear corneal incision (Additional file 1, Figure S1, panel A) and samples at time points 24 and 48 hours for limbal incision (Additional file 2, Figure S1, panel B)), due to a limitation in a loading volume for 1st dimension of 2-DE and due to a limited amount of AH sample available

  • The fact that most of the protective proteins detected in healthy AH [19] is not seen in surgery AH samples could imply that a mechanism of protein release into AH after surgery can be rather a global response to the surgery than the increase in amount of protective proteins found in healthy AH as one could expect

Read more

Summary

Introduction

The aqueous humor (AH), a liquid of the anterior and posterior chamber of the eye, comprises many proteins with various roles and important biological functions Many of these proteins have not been identified yet and their functions in AH are still unknown. Our present study extends our previous work and analyses AH following two types of cataract surgery incision procedures (clear corneal and limbal incisions) by using two dimensional gel electrophoresis (2-DE) and liquid chromatography tandem mass spectrometry (LC-MS/MS). Both incision protocols are commonly used during cataract surgeries, the difference in protein composition and their release into AH following each surgery has never been systematically compared and remains unclear. There are several concerns regarding the use of the clear corneal procedure - the risk of wound leakage and inflow of extraocular fluid in unsutured corneal incision with possible postoperative ingress of bacteria into the anterior chamber [6,7] and a failure in the mechanism of bacterial clearance from the anterior chamber related to less postoperative inflammation [8], which otherwise will prevent or decrease a risk of a clinical disease

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call