Abstract

An investigation on the thermal hydraulic characteristics of the passive residual heat removal system (PRHRS) which is used in an integral pressurized water reactor (INSURE-100) is presented in this paper. The main components of primary coolant system are enclosed in reactor vessel. Primary fluid flow circle is natural circulation. The PRHRS can remove the energy from the primary side as long as the residual heat exchanger (RHE) is submerged in the emergency cooldown tank (ECT). The parameter study is performed by considering the effects of an effective height between the steam generators and the RHE and a valve actuation time, which are useful for the design of the PRHRS. The mass flow in the PRHRS has been affected by the height difference between the steam generators and the RHE. The pressure peak of the primary side and PRHRS has been affected by the valve action time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.