Abstract

The pressure profiles on the horizontal and vertical step faces of a stepped spillway in the fully developed skimming flow region were measured. These observations allow to provide generalized equations that enable designers to analyze the amount and the location of negative pressures along the steps. The step locations subjected to negative pressure are also discussed including an analysis of the duration of the negative pressures. On the horizontal step faces, negative pressure were only observed on their upstream half for dimensionless discharges larger than dc/h = 1.3. On the vertical step faces, only the region close to the adjacent horizontal face was not subjected to negative pressure

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.