Abstract
This paper presents the test results of reinforced precast lintels made of autoclaved aerated concrete (AAC) used to cover window openings in walls made of AAC masonry units. Walls were confined with reinforced lightweight concrete. The two variants of wall confinement with different way of lintel support and the static diagram of a simply supported beam and a constrained beam were tested. Cracks and deformations of test models around window openings were recorded with the Aramis software for non-contact measurements of displacements. Failure of lintels caused the loss of load capacity of test models. Lintels were cracked in the same way, but the sequence of crack formation and their location were different. The test results were compared with the test made for similar walls confined with ordinary concrete. Additional tie-columns did not significantly affected the load capacity of the test models contrary to the walls confined with ordinary concrete.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.