Abstract
Objective: This study aimed to investigated the effect of light, temperature, pH, peroxides, trace metals, and buffer type on the chemical stability of polysorbate 80 (PS80) obtained from the three key manufactures. Methods: We used a fast liquid chromatography-evaporative light scattering detector that allowed the monitoring of PS80 decay over time. For data analysis, we investigated the change in the peak area percentage of the compound over time. Results: At pH 6.0 in histidine buffer, PS80-B was more sensitive than PS80-A and PS80-C. The PS80 from the three different sources degraded significantly with varying performance levels when exposed to light, temperature of 40 °C, peroxides, and trace metals over time. Conclusion: Our results provide an improved understanding of the stability of PS80 obtained from the three different sources under different conditions, which provides a basis for the selection of the appropriate grade of PS80 according to the specific requirements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.