Abstract

Polyoxyethylene macromonomers are analyzed by one-dimensional liquid chromatography under different conditions, depending on the required information. These samples may contain polyethylene glycol (PEG) and the corresponding di(meth)acrylate besides the desired mono(meth)acrylate. The molar mass distribution (MMD) of the PEG and the monoester can be obtained by liquid adsorption chromatography (LAC) on a reversed-phase column in acetone-water with a gradient from 10% to 20% acetone. The MMD of the diesters can be obtained with isocratic elution by liquid chromatography at critical conditions (LCCC) on a reversed-phase column in 31% acetone, or using size-exclusion conditions for PEG and LAC conditions for the end groups, which is the case in 40-55% acetone. The absolute amount of the series with different functionality can be obtained by LCCC in ternary mobile phases consisting of acetone, methanol, and water along the critical adsorption line. Under such conditions, all series elute as narrow peaks (regardless their MMD), which can easily be integrated and quantified.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.