Abstract

This paper addresses the irreversible permanent magnet (PM) demagnetization analysis of hybrid excitation flux switching motor (HEFSM) with outer-rotor configuration. PM demagnetization cause the PM strength used in the motor significantly reduces and hence contributes less torque performance. The study is focused on thermal analysis and conducted at various temperature up to as high as 180 degrees Celsius which has a tendency to be demagnetized. Therefore, PM demagnetization is among a critical issue and influences the choice of the applied motor. The analysis is carried out based on finite element method (FEM) and percentage of PM demagnetization is then calculated. Finally, based on simulated and calculated results the final design outer-rotor HEFSM has only 0.85 percent PM demagnetization at very high temperature and obviously the is no PM demagnetization at normal operating conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.