Abstract

An alternative ultrafiltration membrane integrity test utilizing magnetic nanoparticle as a surrogate has been investigated in previous studies, but the absence of a feasible estimation model for the degree of membrane damage causes that this simple membrane integrity test would be not applied easily. This study proposed a calculating model to predict membrane defect size, and investigated the theoretic resolution of the integrity test method. The results obtained with the evolved prediction model D, which is based on Darcy’s law and Bernoulli equation, were satisfactory in predicting the membrane defect size. In this study, this integrity test method had about 39.33% probability to have a theoretic resolution of 3μm or less under common experimental conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.