Abstract
In recent years, the substantial upsurge of electricity demand has directly impacted the performance of the distribution networks concerning the active power losses and voltage drops. In such circumstances, the distributed generators (DGs) could uphold these concerns if they are optimally deployed in terms of sizing and placement. For this reason, in current research, the optimal deployment of DGs has been proposed with the plant propagation algorithm (PPA) to simultaneously maximize the total active power loss reduction and to upgrade the magnitude of the minimum bus voltage. Alongside, the authors have examined four rounds of DGs. In that context, the optimal deployment of one DG is investigated in the first round. In each succeeding round, the number of DGs is increased: in the second round, this investigation is carried out for two DGs, for three DGs in the third round, and finally, for four DGs in the fourth round of the investigation. The effectiveness of the proposed PPA has been tested on IEEE 33 and 69-bus test networks in the load flow analysis, and results are compared with the standard optimization algorithms. Thereafter, a post deployment economic assessment based on loss calculation has been undertaken out as well. The ANOVA test has also been performed for statistical evaluation of standard algorithms. The simulation results exhibit that the proposed algorithm outdo other algorithms both technically and economically. It has been seen that as the deployment of DGs is increased, the total active power losses and voltage drops are also reduced. In terms of economic assessments, the total cost decreases with the increased deployment of DGs in IEEE 33-bus test network, whereas, the total cost increases with the increased deployment of DGs in IEEE 69-bus test network.
Highlights
In the last few decades, the load demand has grown extensively [1]
IEEE 33-bus distribution network is designated as test network 1, whereas IEEE 69-bus distribution network is designated as test network 2 [53]
The optimal sizes and places of the distributed generators (DGs) have been searched using the propagation algorithm (PPA), such that to maximize the reduction of the total active power loss and to upgrade the magnitude of the minimum bus voltage
Summary
In the last few decades, the load demand has grown extensively [1]. As a result, the overall line losses and voltage drops are increased in the electrical networks. It has turned out that only 20% of the reinforcement serves the peak load demand for only 5% of the total operating time [5]. Another solution leads to the incorporation of the DGs into the distribution systems. The integration of DGs outcome in an economical solution provided to their optimal deployment, as they can inject/absorb both active and reactive powers. In this way line losses and voltage drops could be minimized and the overall steadiness of the system increases [8], [9]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.